public class TLcdAIXM51ArrivalFeederLegTimeSlice extends TLcdAIXM51AbstractApproachLegTimeSlice
Modifier and Type | Field and Description |
---|---|
static TLcdDataProperty |
AIRCRAFT_CATEGORY_PROPERTY
Data property that maps to the
aircraftCategory element. |
static TLcdDataProperty |
ALTITUDE_INTERPRETATION_PROPERTY
Data property that maps to the
altitudeInterpretation element. |
static TLcdDataProperty |
ALTITUDE_OVERRIDE_ATC_PROPERTY
Data property that maps to the
altitudeOverrideATC element. |
static TLcdDataProperty |
ALTITUDE_OVERRIDE_REFERENCE_PROPERTY
Data property that maps to the
altitudeOverrideReference element. |
static TLcdDataProperty |
ANGLE_PROPERTY
Data property that maps to the
angle element. |
static TLcdDataProperty |
ANNOTATION_PROPERTY
Data property that maps to the
annotation element. |
static TLcdDataProperty |
APPROACH_PROPERTY
Data property that maps to the
approach element. |
static TLcdDataProperty |
ARC_CENTRE_PROPERTY
Data property that maps to the
arcCentre element. |
static TLcdDataProperty |
BANK_ANGLE_PROPERTY
Data property that maps to the
bankAngle element. |
static TLcdDataProperty |
CORRECTION_NUMBER_PROPERTY
Data property that maps to the
correctionNumber element. |
static TLcdDataProperty |
COURSE_DIRECTION_PROPERTY
Data property that maps to the
courseDirection element. |
static TLcdDataProperty |
COURSE_PROPERTY
Data property that maps to the
course element. |
static TLcdDataProperty |
COURSE_TYPE_PROPERTY
Data property that maps to the
courseType element. |
static TLcdDataProperty |
DESIGN_SURFACE_PROPERTY
Data property that maps to the
designSurface element. |
static TLcdDataProperty |
DISTANCE_PROPERTY
Data property that maps to the
distance element. |
static TLcdDataProperty |
DURATION_PROPERTY
Data property that maps to the
duration element. |
static TLcdDataProperty |
END_CONDITION_DESIGNATOR_PROPERTY
Data property that maps to the
endConditionDesignator element. |
static TLcdDataProperty |
END_POINT_PROPERTY
Data property that maps to the
endPoint element. |
static TLcdDataProperty |
EXTENSION_PROPERTY
Data property that maps to the
extension element. |
static TLcdDataProperty |
FEATURE_LIFETIME_PROPERTY
Data property that maps to the
featureLifetime element. |
static TLcdDataProperty |
HOLDING_PROPERTY
Data property that maps to the
holding element. |
static TLcdDataProperty |
INTERPRETATION_PROPERTY
Data property that maps to the
interpretation element. |
static TLcdDataProperty |
LEG_PATH_PROPERTY
Data property that maps to the
legPath element. |
static TLcdDataProperty |
LEG_TYPE_ARINC_PROPERTY
Data property that maps to the
legTypeARINC element. |
static TLcdDataProperty |
LENGTH_PROPERTY
Data property that maps to the
length element. |
static TLcdDataProperty |
LOWER_LIMIT_ALTITUDE_PROPERTY
Data property that maps to the
lowerLimitAltitude element. |
static TLcdDataProperty |
LOWER_LIMIT_REFERENCE_PROPERTY
Data property that maps to the
lowerLimitReference element. |
static TLcdDataProperty |
PROCEDURE_TURN_REQUIRED_PROPERTY
Data property that maps to the
procedureTurnRequired element. |
static TLcdDataProperty |
REQUIRED_NAVIGATION_PERFORMANCE_PROPERTY
Data property that maps to the
requiredNavigationPerformance element. |
static TLcdDataProperty |
SEQUENCE_NUMBER_PROPERTY
Data property that maps to the
sequenceNumber element. |
static TLcdDataProperty |
SPEED_INTERPRETATION_PROPERTY
Data property that maps to the
speedInterpretation element. |
static TLcdDataProperty |
SPEED_LIMIT_PROPERTY
Data property that maps to the
speedLimit element. |
static TLcdDataProperty |
SPEED_REFERENCE_PROPERTY
Data property that maps to the
speedReference element. |
static TLcdDataProperty |
START_POINT_PROPERTY
Data property that maps to the
startPoint element. |
static TLcdDataProperty |
TIME_SLICE_METADATA_PROPERTY
Data property that maps to the
timeSliceMetadata element. |
static TLcdDataProperty |
TRAJECTORY_PROPERTY
Data property that maps to the
trajectory element. |
static TLcdDataProperty |
TURN_DIRECTION_PROPERTY
Data property that maps to the
turnDirection element. |
static TLcdDataProperty |
UPPER_LIMIT_ALTITUDE_PROPERTY
Data property that maps to the
upperLimitAltitude element. |
static TLcdDataProperty |
UPPER_LIMIT_REFERENCE_PROPERTY
Data property that maps to the
upperLimitReference element. |
static TLcdDataProperty |
VERTICAL_ANGLE_PROPERTY
Data property that maps to the
verticalAngle element. |
DATA_SOURCE_PROPERTY, VALID_TIME_PROPERTY
DESCRIPTION_PROPERTY, DESCRIPTION_REFERENCE_PROPERTY, ID_PROPERTY, IDENTIFIER_PROPERTY, META_DATA_PROPERTY_PROPERTY, NAME_PROPERTY
Constructor and Description |
---|
TLcdAIXM51ArrivalFeederLegTimeSlice() |
TLcdAIXM51ArrivalFeederLegTimeSlice(TLcdDataType aType) |
Modifier and Type | Method and Description |
---|---|
List<TLcdAIXM51AircraftCharacteristic> |
getAircraftCategory()
Gets the value of the
AIRCRAFT_CATEGORY_PROPERTY property adapted to a list of TLcdAIXM51AircraftCharacteristic instances. |
TLcdAIXM51CodeAltitudeUse |
getAltitudeInterpretation()
Returns the role value contained in the value of the
ALTITUDE_INTERPRETATION_PROPERTY property. |
TLcdAIXM51ValDistanceVertical |
getAltitudeOverrideATC()
Returns the value of the property that maps to the
altitudeOverrideATC element. |
TLcdAIXM51CodeVerticalReference |
getAltitudeOverrideReference()
Returns the role value contained in the value of the
ALTITUDE_OVERRIDE_REFERENCE_PROPERTY property. |
TLcdAIXM51Feature<TLcdAIXM51AngleIndicationTimeSlice> |
getAngle()
Returns the role value contained in the value of the
ANGLE_PROPERTY property. |
List<TLcdAIXM51Note> |
getAnnotation()
Gets the value of the
ANNOTATION_PROPERTY property adapted to a list of TLcdAIXM51Note instances. |
TLcdAIXM51Feature<TLcdAIXM51InstrumentApproachProcedureTimeSlice> |
getApproach()
Returns the role value contained in the value of the
APPROACH_PROPERTY property. |
TLcdAIXM51TerminalSegmentPoint |
getArcCentre()
Returns the role value contained in the value of the
ARC_CENTRE_PROPERTY property. |
Double |
getBankAngle()
Returns the role value contained in the value of the
BANK_ANGLE_PROPERTY property. |
long |
getCorrectionNumber()
Returns the value of the property that maps to the
correctionNumber element. |
Double |
getCourse()
Returns the role value contained in the value of the
COURSE_PROPERTY property. |
TLcdAIXM51CodeDirectionReference |
getCourseDirection()
Returns the role value contained in the value of the
COURSE_DIRECTION_PROPERTY property. |
TLcdAIXM51CodeCourse |
getCourseType()
Returns the role value contained in the value of the
COURSE_TYPE_PROPERTY property. |
List<TLcdAIXM51ObstacleAssessmentArea> |
getDesignSurface()
Gets the value of the
DESIGN_SURFACE_PROPERTY property adapted to a list of TLcdAIXM51ObstacleAssessmentArea instances. |
TLcdAIXM51Feature<TLcdAIXM51DistanceIndicationTimeSlice> |
getDistance()
Returns the role value contained in the value of the
DISTANCE_PROPERTY property. |
TLcdAIXM51ValDuration |
getDuration()
Returns the value of the property that maps to the
duration element. |
TLcdAIXM51CodeSegmentTermination |
getEndConditionDesignator()
Returns the role value contained in the value of the
END_CONDITION_DESIGNATOR_PROPERTY property. |
TLcdAIXM51TerminalSegmentPoint |
getEndPoint()
Returns the role value contained in the value of the
END_POINT_PROPERTY property. |
List<TLcdAIXM51AbstractExtension> |
getExtension()
Gets the value of the
EXTENSION_PROPERTY property adapted to a list of TLcdAIXM51AbstractExtension instances. |
TLcdGML32AbstractTimePrimitive |
getFeatureLifetime()
Returns the value of the property that maps to the
featureLifetime element. |
TLcdAIXM51HoldingUse |
getHolding()
Returns the role value contained in the value of the
HOLDING_PROPERTY property. |
ELcdAIXM51Interpretation |
getInterpretation()
Returns the value of the property that maps to the
interpretation element. |
TLcdAIXM51CodeTrajectory |
getLegPath()
Returns the role value contained in the value of the
LEG_PATH_PROPERTY property. |
TLcdAIXM51CodeSegmentPath |
getLegTypeARINC()
Returns the role value contained in the value of the
LEG_TYPE_ARINC_PROPERTY property. |
TLcdAIXM51ValDistance |
getLength()
Returns the value of the property that maps to the
length element. |
TLcdAIXM51ValDistanceVertical |
getLowerLimitAltitude()
Returns the value of the property that maps to the
lowerLimitAltitude element. |
TLcdAIXM51CodeVerticalReference |
getLowerLimitReference()
Returns the role value contained in the value of the
LOWER_LIMIT_REFERENCE_PROPERTY property. |
TLcdAIXM51CodeYesNo |
getProcedureTurnRequired()
Returns the role value contained in the value of the
PROCEDURE_TURN_REQUIRED_PROPERTY property. |
Double |
getRequiredNavigationPerformance()
Returns the role value contained in the value of the
REQUIRED_NAVIGATION_PERFORMANCE_PROPERTY property. |
long |
getSequenceNumber()
Returns the value of the property that maps to the
sequenceNumber element. |
TLcdAIXM51CodeAltitudeUse |
getSpeedInterpretation()
Returns the role value contained in the value of the
SPEED_INTERPRETATION_PROPERTY property. |
TLcdAIXM51ValSpeed |
getSpeedLimit()
Returns the value of the property that maps to the
speedLimit element. |
TLcdAIXM51CodeSpeedReference |
getSpeedReference()
Returns the role value contained in the value of the
SPEED_REFERENCE_PROPERTY property. |
TLcdAIXM51TerminalSegmentPoint |
getStartPoint()
Returns the role value contained in the value of the
START_POINT_PROPERTY property. |
TLcdAIXM51FeatureTimeSliceMetadataProperty |
getTimeSliceMetadata()
Returns the value of the property that maps to the
timeSliceMetadata element. |
TLcdAIXM51Curve |
getTrajectory()
Returns the role value contained in the value of the
TRAJECTORY_PROPERTY property. |
TLcdAIXM51CodeDirectionTurn |
getTurnDirection()
Returns the role value contained in the value of the
TURN_DIRECTION_PROPERTY property. |
TLcdAIXM51ValDistanceVertical |
getUpperLimitAltitude()
Returns the value of the property that maps to the
upperLimitAltitude element. |
TLcdAIXM51CodeVerticalReference |
getUpperLimitReference()
Returns the role value contained in the value of the
UPPER_LIMIT_REFERENCE_PROPERTY property. |
Double |
getVerticalAngle()
Returns the role value contained in the value of the
VERTICAL_ANGLE_PROPERTY property. |
void |
setAltitudeInterpretation(TLcdAIXM51CodeAltitudeUse aValue)
Sets the value of the property that maps to the
altitudeInterpretation element. |
void |
setAltitudeOverrideATC(TLcdAIXM51ValDistanceVertical aValue)
Sets the value of the property that maps to the
altitudeOverrideATC element. |
void |
setAltitudeOverrideReference(TLcdAIXM51CodeVerticalReference aValue)
Sets the value of the property that maps to the
altitudeOverrideReference element. |
void |
setAngle(TLcdAIXM51Feature<TLcdAIXM51AngleIndicationTimeSlice> aValue)
Sets the value of the property that maps to the
angle element. |
void |
setApproach(TLcdAIXM51Feature<TLcdAIXM51InstrumentApproachProcedureTimeSlice> aValue)
Sets the value of the property that maps to the
approach element. |
void |
setArcCentre(TLcdAIXM51TerminalSegmentPoint aValue)
Sets the value of the property that maps to the
arcCentre element. |
void |
setBankAngle(Double aValue)
Sets the value of the property that maps to the
bankAngle element. |
void |
setCorrectionNumber(long aValue)
Sets the value of the property that maps to the
correctionNumber element. |
void |
setCourse(Double aValue)
Sets the value of the property that maps to the
course element. |
void |
setCourseDirection(TLcdAIXM51CodeDirectionReference aValue)
Sets the value of the property that maps to the
courseDirection element. |
void |
setCourseType(TLcdAIXM51CodeCourse aValue)
Sets the value of the property that maps to the
courseType element. |
void |
setDistance(TLcdAIXM51Feature<TLcdAIXM51DistanceIndicationTimeSlice> aValue)
Sets the value of the property that maps to the
distance element. |
void |
setDuration(TLcdAIXM51ValDuration aValue)
Sets the value of the property that maps to the
duration element. |
void |
setEndConditionDesignator(TLcdAIXM51CodeSegmentTermination aValue)
Sets the value of the property that maps to the
endConditionDesignator element. |
void |
setEndPoint(TLcdAIXM51TerminalSegmentPoint aValue)
Sets the value of the property that maps to the
endPoint element. |
void |
setFeatureLifetime(TLcdGML32AbstractTimePrimitive aValue)
Sets the value of the property that maps to the
featureLifetime element. |
void |
setHolding(TLcdAIXM51HoldingUse aValue)
Sets the value of the property that maps to the
holding element. |
void |
setInterpretation(ELcdAIXM51Interpretation aValue)
Sets the value of the property that maps to the
interpretation element. |
void |
setLegPath(TLcdAIXM51CodeTrajectory aValue)
Sets the value of the property that maps to the
legPath element. |
void |
setLegTypeARINC(TLcdAIXM51CodeSegmentPath aValue)
Sets the value of the property that maps to the
legTypeARINC element. |
void |
setLength(TLcdAIXM51ValDistance aValue)
Sets the value of the property that maps to the
length element. |
void |
setLowerLimitAltitude(TLcdAIXM51ValDistanceVertical aValue)
Sets the value of the property that maps to the
lowerLimitAltitude element. |
void |
setLowerLimitReference(TLcdAIXM51CodeVerticalReference aValue)
Sets the value of the property that maps to the
lowerLimitReference element. |
void |
setProcedureTurnRequired(TLcdAIXM51CodeYesNo aValue)
Sets the value of the property that maps to the
procedureTurnRequired element. |
void |
setRequiredNavigationPerformance(Double aValue)
Sets the value of the property that maps to the
requiredNavigationPerformance element. |
void |
setSequenceNumber(long aValue)
Sets the value of the property that maps to the
sequenceNumber element. |
void |
setSpeedInterpretation(TLcdAIXM51CodeAltitudeUse aValue)
Sets the value of the property that maps to the
speedInterpretation element. |
void |
setSpeedLimit(TLcdAIXM51ValSpeed aValue)
Sets the value of the property that maps to the
speedLimit element. |
void |
setSpeedReference(TLcdAIXM51CodeSpeedReference aValue)
Sets the value of the property that maps to the
speedReference element. |
void |
setStartPoint(TLcdAIXM51TerminalSegmentPoint aValue)
Sets the value of the property that maps to the
startPoint element. |
void |
setTimeSliceMetadata(TLcdAIXM51FeatureTimeSliceMetadataProperty aValue)
Sets the value of the property that maps to the
timeSliceMetadata element. |
void |
setTrajectory(TLcdAIXM51Curve aValue)
Sets the value of the property that maps to the
trajectory element. |
void |
setTurnDirection(TLcdAIXM51CodeDirectionTurn aValue)
Sets the value of the property that maps to the
turnDirection element. |
void |
setUpperLimitAltitude(TLcdAIXM51ValDistanceVertical aValue)
Sets the value of the property that maps to the
upperLimitAltitude element. |
void |
setUpperLimitReference(TLcdAIXM51CodeVerticalReference aValue)
Sets the value of the property that maps to the
upperLimitReference element. |
void |
setVerticalAngle(Double aValue)
Sets the value of the property that maps to the
verticalAngle element. |
clone, clone, collectShapes, contains2D, contains2D, contains3D, contains3D, getBeginValidTime, getBounds, getEndValidTime, getFocusPoint, getShape, getShapeCount, getTimeBounds, invalidateObject, setValue
getDataSource, getValidTime, setDataSource, setValidTime
getDescription, getDescriptionReference, getId, getIdentifier, getMetaDataProperty, getName, setDescription, setDescriptionReference, setId, setIdentifier
getDataType, getValue, getValue, hasValue, hasValue, setValue, toString
public static final TLcdDataProperty END_CONDITION_DESIGNATOR_PROPERTY
endConditionDesignator
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeSegmentTermination>
.public static final TLcdDataProperty LEG_PATH_PROPERTY
legPath
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeTrajectory>
.public static final TLcdDataProperty LEG_TYPE_ARINC_PROPERTY
legTypeARINC
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeSegmentPath>
.public static final TLcdDataProperty COURSE_PROPERTY
course
element.
The possible values for this property are instances of TLcdAIXM51Optional<Double>
.public static final TLcdDataProperty COURSE_TYPE_PROPERTY
courseType
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeCourse>
.public static final TLcdDataProperty COURSE_DIRECTION_PROPERTY
courseDirection
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeDirectionReference>
.public static final TLcdDataProperty TURN_DIRECTION_PROPERTY
turnDirection
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeDirectionTurn>
.public static final TLcdDataProperty SPEED_LIMIT_PROPERTY
speedLimit
element.
The possible values for this property are instances of TLcdAIXM51ValSpeed
.public static final TLcdDataProperty SPEED_REFERENCE_PROPERTY
speedReference
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeSpeedReference>
.public static final TLcdDataProperty SPEED_INTERPRETATION_PROPERTY
speedInterpretation
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeAltitudeUse>
.public static final TLcdDataProperty BANK_ANGLE_PROPERTY
bankAngle
element.
The possible values for this property are instances of TLcdAIXM51Optional<Double>
.public static final TLcdDataProperty LENGTH_PROPERTY
length
element.
The possible values for this property are instances of TLcdAIXM51ValDistance
.public static final TLcdDataProperty DURATION_PROPERTY
duration
element.
The possible values for this property are instances of TLcdAIXM51ValDuration
.public static final TLcdDataProperty PROCEDURE_TURN_REQUIRED_PROPERTY
procedureTurnRequired
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeYesNo>
.public static final TLcdDataProperty UPPER_LIMIT_ALTITUDE_PROPERTY
upperLimitAltitude
element.
The possible values for this property are instances of TLcdAIXM51ValDistanceVertical
.public static final TLcdDataProperty UPPER_LIMIT_REFERENCE_PROPERTY
upperLimitReference
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeVerticalReference>
.public static final TLcdDataProperty LOWER_LIMIT_ALTITUDE_PROPERTY
lowerLimitAltitude
element.
The possible values for this property are instances of TLcdAIXM51ValDistanceVertical
.public static final TLcdDataProperty LOWER_LIMIT_REFERENCE_PROPERTY
lowerLimitReference
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeVerticalReference>
.public static final TLcdDataProperty ALTITUDE_INTERPRETATION_PROPERTY
altitudeInterpretation
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeAltitudeUse>
.public static final TLcdDataProperty ALTITUDE_OVERRIDE_ATC_PROPERTY
altitudeOverrideATC
element.
The possible values for this property are instances of TLcdAIXM51ValDistanceVertical
.public static final TLcdDataProperty ALTITUDE_OVERRIDE_REFERENCE_PROPERTY
altitudeOverrideReference
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeVerticalReference>
.public static final TLcdDataProperty VERTICAL_ANGLE_PROPERTY
verticalAngle
element.
The possible values for this property are instances of TLcdAIXM51Optional<Double>
.public static final TLcdDataProperty START_POINT_PROPERTY
startPoint
element.
The possible values for this property are instances of TLcdAIXM51Property<TLcdAIXM51TerminalSegmentPoint>
.public static final TLcdDataProperty END_POINT_PROPERTY
endPoint
element.
The possible values for this property are instances of TLcdAIXM51Property<TLcdAIXM51TerminalSegmentPoint>
.public static final TLcdDataProperty TRAJECTORY_PROPERTY
trajectory
element.
The possible values for this property are instances of TLcdAIXM51Property<TLcdAIXM51Curve>
.public static final TLcdDataProperty ARC_CENTRE_PROPERTY
arcCentre
element.
The possible values for this property are instances of TLcdAIXM51Property<TLcdAIXM51TerminalSegmentPoint>
.public static final TLcdDataProperty ANGLE_PROPERTY
angle
element.
The possible values for this property are instances of TLcdAIXM51FeatureAssociation<TLcdAIXM51AngleIndicationTimeSlice>
.public static final TLcdDataProperty DISTANCE_PROPERTY
distance
element.
The possible values for this property are instances of TLcdAIXM51FeatureAssociation<TLcdAIXM51DistanceIndicationTimeSlice>
.public static final TLcdDataProperty AIRCRAFT_CATEGORY_PROPERTY
aircraftCategory
element.
The possible values for this property are instances of List<TLcdAIXM51Property<TLcdAIXM51AircraftCharacteristic>>
.public static final TLcdDataProperty HOLDING_PROPERTY
holding
element.
The possible values for this property are instances of TLcdAIXM51Property<TLcdAIXM51HoldingUse>
.public static final TLcdDataProperty DESIGN_SURFACE_PROPERTY
designSurface
element.
The possible values for this property are instances of List<TLcdAIXM51Property<TLcdAIXM51ObstacleAssessmentArea>>
.public static final TLcdDataProperty ANNOTATION_PROPERTY
annotation
element.
The possible values for this property are instances of List<TLcdAIXM51Property<TLcdAIXM51Note>>
.public static final TLcdDataProperty APPROACH_PROPERTY
approach
element.
The possible values for this property are instances of TLcdAIXM51FeatureAssociation<TLcdAIXM51InstrumentApproachProcedureTimeSlice>
.public static final TLcdDataProperty REQUIRED_NAVIGATION_PERFORMANCE_PROPERTY
requiredNavigationPerformance
element.
The possible values for this property are instances of TLcdAIXM51Optional<Double>
.public static final TLcdDataProperty EXTENSION_PROPERTY
extension
element.
The possible values for this property are instances of List<TLcdAIXM51Link<TLcdAIXM51AbstractExtension>>
.public static final TLcdDataProperty INTERPRETATION_PROPERTY
interpretation
element.
The possible values for this property are instances of ELcdAIXM51Interpretation
.public static final TLcdDataProperty SEQUENCE_NUMBER_PROPERTY
sequenceNumber
element.
The possible values for this property are instances of long
.public static final TLcdDataProperty CORRECTION_NUMBER_PROPERTY
correctionNumber
element.
The possible values for this property are instances of long
.public static final TLcdDataProperty TIME_SLICE_METADATA_PROPERTY
timeSliceMetadata
element.
The possible values for this property are instances of TLcdAIXM51FeatureTimeSliceMetadataProperty
.public static final TLcdDataProperty FEATURE_LIFETIME_PROPERTY
featureLifetime
element.
The possible values for this property are instances of TLcdGML32TimePrimitiveProperty
.public TLcdAIXM51ArrivalFeederLegTimeSlice()
public TLcdAIXM51ArrivalFeederLegTimeSlice(TLcdDataType aType)
public TLcdAIXM51CodeSegmentTermination getEndConditionDesignator()
END_CONDITION_DESIGNATOR_PROPERTY
property. Returns null
if the value of the END_CONDITION_DESIGNATOR_PROPERTY
property is null
.
An indication of the event that allows identifying the end of the leg and the start of the next leg on the procedure. For example, reaching an altitude or outbound timing.
getEndConditionDesignator
in class TLcdAIXM51AbstractSegmentLegTimeSlice
END_CONDITION_DESIGNATOR_PROPERTY
property.TLcdAIXM51Optional
public void setEndConditionDesignator(TLcdAIXM51CodeSegmentTermination aValue)
endConditionDesignator
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the END_CONDITION_DESIGNATOR_PROPERTY
property is set to null
.
An indication of the event that allows identifying the end of the leg and the start of the next leg on the procedure. For example, reaching an altitude or outbound timing.
setEndConditionDesignator
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the END_CONDITION_DESIGNATOR_PROPERTY
property.public TLcdAIXM51CodeTrajectory getLegPath()
LEG_PATH_PROPERTY
property. Returns null
if the value of the LEG_PATH_PROPERTY
property is null
.
A code defining a specific type of flight path such as arc, base turn outbound, base turn inbound, track, proc turn, hold in lieu.
getLegPath
in class TLcdAIXM51AbstractSegmentLegTimeSlice
LEG_PATH_PROPERTY
property.TLcdAIXM51Optional
public void setLegPath(TLcdAIXM51CodeTrajectory aValue)
legPath
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the LEG_PATH_PROPERTY
property is set to null
.
A code defining a specific type of flight path such as arc, base turn outbound, base turn inbound, track, proc turn, hold in lieu.
setLegPath
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the LEG_PATH_PROPERTY
property.public TLcdAIXM51CodeSegmentPath getLegTypeARINC()
LEG_TYPE_ARINC_PROPERTY
property. Returns null
if the value of the LEG_TYPE_ARINC_PROPERTY
property is null
.
A comprehensive description of the 'path and terminator' concept is given in ARINC Specification 424, Attachment 5, Path and Terminator.
getLegTypeARINC
in class TLcdAIXM51AbstractSegmentLegTimeSlice
LEG_TYPE_ARINC_PROPERTY
property.TLcdAIXM51Optional
public void setLegTypeARINC(TLcdAIXM51CodeSegmentPath aValue)
legTypeARINC
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the LEG_TYPE_ARINC_PROPERTY
property is set to null
.
A comprehensive description of the 'path and terminator' concept is given in ARINC Specification 424, Attachment 5, Path and Terminator.
setLegTypeARINC
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the LEG_TYPE_ARINC_PROPERTY
property.public Double getCourse()
COURSE_PROPERTY
property. Returns null
if the value of the COURSE_PROPERTY
property is null
.
The value of the course angle in degrees.
getCourse
in class TLcdAIXM51AbstractSegmentLegTimeSlice
COURSE_PROPERTY
property.TLcdAIXM51Optional
public void setCourse(Double aValue)
course
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the COURSE_PROPERTY
property is set to null
.
The value of the course angle in degrees.
setCourse
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the COURSE_PROPERTY
property.public TLcdAIXM51CodeCourse getCourseType()
COURSE_TYPE_PROPERTY
property. Returns null
if the value of the COURSE_TYPE_PROPERTY
property is null
.
A code indicating the type of course to be observed. E.g. true track, magnetic track, heading, VOR radial, true bearing, magnetic bearing.
getCourseType
in class TLcdAIXM51AbstractSegmentLegTimeSlice
COURSE_TYPE_PROPERTY
property.TLcdAIXM51Optional
public void setCourseType(TLcdAIXM51CodeCourse aValue)
courseType
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the COURSE_TYPE_PROPERTY
property is set to null
.
A code indicating the type of course to be observed. E.g. true track, magnetic track, heading, VOR radial, true bearing, magnetic bearing.
setCourseType
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the COURSE_TYPE_PROPERTY
property.public TLcdAIXM51CodeDirectionReference getCourseDirection()
COURSE_DIRECTION_PROPERTY
property. Returns null
if the value of the COURSE_DIRECTION_PROPERTY
property is null
.
Indicates flight direction to/from the navaid providing the course guidance.
getCourseDirection
in class TLcdAIXM51AbstractSegmentLegTimeSlice
COURSE_DIRECTION_PROPERTY
property.TLcdAIXM51Optional
public void setCourseDirection(TLcdAIXM51CodeDirectionReference aValue)
courseDirection
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the COURSE_DIRECTION_PROPERTY
property is set to null
.
Indicates flight direction to/from the navaid providing the course guidance.
setCourseDirection
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the COURSE_DIRECTION_PROPERTY
property.public TLcdAIXM51CodeDirectionTurn getTurnDirection()
TURN_DIRECTION_PROPERTY
property. Returns null
if the value of the TURN_DIRECTION_PROPERTY
property is null
.
A code indicating the direction of the turn.
getTurnDirection
in class TLcdAIXM51AbstractSegmentLegTimeSlice
TURN_DIRECTION_PROPERTY
property.TLcdAIXM51Optional
public void setTurnDirection(TLcdAIXM51CodeDirectionTurn aValue)
turnDirection
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the TURN_DIRECTION_PROPERTY
property is set to null
.
A code indicating the direction of the turn.
setTurnDirection
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the TURN_DIRECTION_PROPERTY
property.public TLcdAIXM51ValSpeed getSpeedLimit()
speedLimit
element.
The value of the speed limit on the procedure leg. Rules: As a plausibility rule, value should be equivalent to between 0 and 400, when expressed in Km/h.
getSpeedLimit
in class TLcdAIXM51AbstractSegmentLegTimeSlice
SPEED_LIMIT_PROPERTY
property.public void setSpeedLimit(TLcdAIXM51ValSpeed aValue)
speedLimit
element.
The value of the speed limit on the procedure leg. Rules: As a plausibility rule, value should be equivalent to between 0 and 400, when expressed in Km/h.
setSpeedLimit
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the value to set for the SPEED_LIMIT_PROPERTY
property.public TLcdAIXM51CodeSpeedReference getSpeedReference()
SPEED_REFERENCE_PROPERTY
property. Returns null
if the value of the SPEED_REFERENCE_PROPERTY
property is null
.
A code indicating the reference system for a speed value.
getSpeedReference
in class TLcdAIXM51AbstractSegmentLegTimeSlice
SPEED_REFERENCE_PROPERTY
property.TLcdAIXM51Optional
public void setSpeedReference(TLcdAIXM51CodeSpeedReference aValue)
speedReference
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the SPEED_REFERENCE_PROPERTY
property is set to null
.
A code indicating the reference system for a speed value.
setSpeedReference
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the SPEED_REFERENCE_PROPERTY
property.public TLcdAIXM51CodeAltitudeUse getSpeedInterpretation()
SPEED_INTERPRETATION_PROPERTY
property. Returns null
if the value of the SPEED_INTERPRETATION_PROPERTY
property is null
.
A code indicating how the speed attributes of a procedure leg should be interpreted.
getSpeedInterpretation
in class TLcdAIXM51AbstractSegmentLegTimeSlice
SPEED_INTERPRETATION_PROPERTY
property.TLcdAIXM51Optional
public void setSpeedInterpretation(TLcdAIXM51CodeAltitudeUse aValue)
speedInterpretation
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the SPEED_INTERPRETATION_PROPERTY
property is set to null
.
A code indicating how the speed attributes of a procedure leg should be interpreted.
setSpeedInterpretation
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the SPEED_INTERPRETATION_PROPERTY
property.public Double getBankAngle()
BANK_ANGLE_PROPERTY
property. Returns null
if the value of the BANK_ANGLE_PROPERTY
property is null
.
The recommended bank angle of the aircraft on the turn. Rules: As a plausibility rule, value should be between 5 and 35 degrees.
getBankAngle
in class TLcdAIXM51AbstractSegmentLegTimeSlice
BANK_ANGLE_PROPERTY
property.TLcdAIXM51Optional
public void setBankAngle(Double aValue)
bankAngle
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the BANK_ANGLE_PROPERTY
property is set to null
.
The recommended bank angle of the aircraft on the turn. Rules: As a plausibility rule, value should be between 5 and 35 degrees.
setBankAngle
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the BANK_ANGLE_PROPERTY
property.public TLcdAIXM51ValDistance getLength()
length
element.
Length of the segment
getLength
in class TLcdAIXM51AbstractSegmentLegTimeSlice
LENGTH_PROPERTY
property.public void setLength(TLcdAIXM51ValDistance aValue)
length
element.
Length of the segment
setLength
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the value to set for the LENGTH_PROPERTY
property.public TLcdAIXM51ValDuration getDuration()
duration
element.
Segment duration
getDuration
in class TLcdAIXM51AbstractSegmentLegTimeSlice
DURATION_PROPERTY
property.public void setDuration(TLcdAIXM51ValDuration aValue)
duration
element.
Segment duration
setDuration
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the value to set for the DURATION_PROPERTY
property.public TLcdAIXM51CodeYesNo getProcedureTurnRequired()
PROCEDURE_TURN_REQUIRED_PROPERTY
property. Returns null
if the value of the PROCEDURE_TURN_REQUIRED_PROPERTY
property is null
.
Indicates if a procedure turn is required at the end of the segmentleg. Default is No.
getProcedureTurnRequired
in class TLcdAIXM51AbstractSegmentLegTimeSlice
PROCEDURE_TURN_REQUIRED_PROPERTY
property.TLcdAIXM51Optional
public void setProcedureTurnRequired(TLcdAIXM51CodeYesNo aValue)
procedureTurnRequired
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the PROCEDURE_TURN_REQUIRED_PROPERTY
property is set to null
.
Indicates if a procedure turn is required at the end of the segmentleg. Default is No.
setProcedureTurnRequired
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the PROCEDURE_TURN_REQUIRED_PROPERTY
property.public TLcdAIXM51ValDistanceVertical getUpperLimitAltitude()
upperLimitAltitude
element.
The value of the upper altitude used with codeDescrDistVer: At or below the higher altitude. Between the lower and the upper altitude.
getUpperLimitAltitude
in class TLcdAIXM51AbstractSegmentLegTimeSlice
UPPER_LIMIT_ALTITUDE_PROPERTY
property.public void setUpperLimitAltitude(TLcdAIXM51ValDistanceVertical aValue)
upperLimitAltitude
element.
The value of the upper altitude used with codeDescrDistVer: At or below the higher altitude. Between the lower and the upper altitude.
setUpperLimitAltitude
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the value to set for the UPPER_LIMIT_ALTITUDE_PROPERTY
property.public TLcdAIXM51CodeVerticalReference getUpperLimitReference()
UPPER_LIMIT_REFERENCE_PROPERTY
property. Returns null
if the value of the UPPER_LIMIT_REFERENCE_PROPERTY
property is null
.
A code indicating the reference for a vertical distance. Two series of values exist: 1) real distance: from GND, from the MSL, from the WGS-84 ellipsoid 2) pressure distance: QFE, QNH, STD.
getUpperLimitReference
in class TLcdAIXM51AbstractSegmentLegTimeSlice
UPPER_LIMIT_REFERENCE_PROPERTY
property.TLcdAIXM51Optional
public void setUpperLimitReference(TLcdAIXM51CodeVerticalReference aValue)
upperLimitReference
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the UPPER_LIMIT_REFERENCE_PROPERTY
property is set to null
.
A code indicating the reference for a vertical distance. Two series of values exist: 1) real distance: from GND, from the MSL, from the WGS-84 ellipsoid 2) pressure distance: QFE, QNH, STD.
setUpperLimitReference
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the UPPER_LIMIT_REFERENCE_PROPERTY
property.public TLcdAIXM51ValDistanceVertical getLowerLimitAltitude()
lowerLimitAltitude
element.
The lower limit altitude. used with codeDescrDistVer: At or above the lower altitude. At the lower altitude Between the lower and the upper altitude. Lower altitude is recommended. Expect lower altitude by ATC.
getLowerLimitAltitude
in class TLcdAIXM51AbstractSegmentLegTimeSlice
LOWER_LIMIT_ALTITUDE_PROPERTY
property.public void setLowerLimitAltitude(TLcdAIXM51ValDistanceVertical aValue)
lowerLimitAltitude
element.
The lower limit altitude. used with codeDescrDistVer: At or above the lower altitude. At the lower altitude Between the lower and the upper altitude. Lower altitude is recommended. Expect lower altitude by ATC.
setLowerLimitAltitude
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the value to set for the LOWER_LIMIT_ALTITUDE_PROPERTY
property.public TLcdAIXM51CodeVerticalReference getLowerLimitReference()
LOWER_LIMIT_REFERENCE_PROPERTY
property. Returns null
if the value of the LOWER_LIMIT_REFERENCE_PROPERTY
property is null
.
A code indicating the reference for a vertical distance. Two series of values exist: 1) real distance: from GND, from the MSL, from the WGS-84 ellipsoid 2) pressure distance: QFE, QNH, STD.
getLowerLimitReference
in class TLcdAIXM51AbstractSegmentLegTimeSlice
LOWER_LIMIT_REFERENCE_PROPERTY
property.TLcdAIXM51Optional
public void setLowerLimitReference(TLcdAIXM51CodeVerticalReference aValue)
lowerLimitReference
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the LOWER_LIMIT_REFERENCE_PROPERTY
property is set to null
.
A code indicating the reference for a vertical distance. Two series of values exist: 1) real distance: from GND, from the MSL, from the WGS-84 ellipsoid 2) pressure distance: QFE, QNH, STD.
setLowerLimitReference
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the LOWER_LIMIT_REFERENCE_PROPERTY
property.public TLcdAIXM51CodeAltitudeUse getAltitudeInterpretation()
ALTITUDE_INTERPRETATION_PROPERTY
property. Returns null
if the value of the ALTITUDE_INTERPRETATION_PROPERTY
property is null
.
A code indicating how the altitude attributes of a procedure leg should be interpreted.
getAltitudeInterpretation
in class TLcdAIXM51AbstractSegmentLegTimeSlice
ALTITUDE_INTERPRETATION_PROPERTY
property.TLcdAIXM51Optional
public void setAltitudeInterpretation(TLcdAIXM51CodeAltitudeUse aValue)
altitudeInterpretation
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the ALTITUDE_INTERPRETATION_PROPERTY
property is set to null
.
A code indicating how the altitude attributes of a procedure leg should be interpreted.
setAltitudeInterpretation
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the ALTITUDE_INTERPRETATION_PROPERTY
property.public TLcdAIXM51ValDistanceVertical getAltitudeOverrideATC()
altitudeOverrideATC
element.
Alternate altitude when directed by Air Traffic Control
getAltitudeOverrideATC
in class TLcdAIXM51AbstractSegmentLegTimeSlice
ALTITUDE_OVERRIDE_ATC_PROPERTY
property.public void setAltitudeOverrideATC(TLcdAIXM51ValDistanceVertical aValue)
altitudeOverrideATC
element.
Alternate altitude when directed by Air Traffic Control
setAltitudeOverrideATC
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the value to set for the ALTITUDE_OVERRIDE_ATC_PROPERTY
property.public TLcdAIXM51CodeVerticalReference getAltitudeOverrideReference()
ALTITUDE_OVERRIDE_REFERENCE_PROPERTY
property. Returns null
if the value of the ALTITUDE_OVERRIDE_REFERENCE_PROPERTY
property is null
.
A code indicating the reference for a vertical distance. Two series of values exist: 1) real distance: from GND, from the MSL, from the WGS-84 ellipsoid 2) pressure distance: QFE, QNH, STD.
getAltitudeOverrideReference
in class TLcdAIXM51AbstractSegmentLegTimeSlice
ALTITUDE_OVERRIDE_REFERENCE_PROPERTY
property.TLcdAIXM51Optional
public void setAltitudeOverrideReference(TLcdAIXM51CodeVerticalReference aValue)
altitudeOverrideReference
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the ALTITUDE_OVERRIDE_REFERENCE_PROPERTY
property is set to null
.
A code indicating the reference for a vertical distance. Two series of values exist: 1) real distance: from GND, from the MSL, from the WGS-84 ellipsoid 2) pressure distance: QFE, QNH, STD.
setAltitudeOverrideReference
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the ALTITUDE_OVERRIDE_REFERENCE_PROPERTY
property.public Double getVerticalAngle()
VERTICAL_ANGLE_PROPERTY
property. Returns null
if the value of the VERTICAL_ANGLE_PROPERTY
property is null
.
The value of the vertical climb angle of the aircraft on the procedure leg. A negative value means descent. Rules: As a plausibility rule, value should be between -10 and +50 degrees.
getVerticalAngle
in class TLcdAIXM51AbstractSegmentLegTimeSlice
VERTICAL_ANGLE_PROPERTY
property.TLcdAIXM51Optional
public void setVerticalAngle(Double aValue)
verticalAngle
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the VERTICAL_ANGLE_PROPERTY
property is set to null
.
The value of the vertical climb angle of the aircraft on the procedure leg. A negative value means descent. Rules: As a plausibility rule, value should be between -10 and +50 degrees.
setVerticalAngle
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the VERTICAL_ANGLE_PROPERTY
property.public TLcdAIXM51TerminalSegmentPoint getStartPoint()
START_POINT_PROPERTY
property. Returns null
if the value of the START_POINT_PROPERTY
property is null
.
The point used to indicate the beginning of a segment.
getStartPoint
in class TLcdAIXM51AbstractSegmentLegTimeSlice
START_POINT_PROPERTY
property.TLcdAIXM51Property
public void setStartPoint(TLcdAIXM51TerminalSegmentPoint aValue)
startPoint
element. to a new instance of the association class TLcdAIXM51Property
initialized with the given role value. In case the given role value is null
, the START_POINT_PROPERTY
property is set to null
.
The point used to indicate the beginning of a segment.
setStartPoint
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the START_POINT_PROPERTY
property.public TLcdAIXM51TerminalSegmentPoint getEndPoint()
END_POINT_PROPERTY
property. Returns null
if the value of the END_POINT_PROPERTY
property is null
.
The point used to indicate the end of a segment.
getEndPoint
in class TLcdAIXM51AbstractSegmentLegTimeSlice
END_POINT_PROPERTY
property.TLcdAIXM51Property
public void setEndPoint(TLcdAIXM51TerminalSegmentPoint aValue)
endPoint
element. to a new instance of the association class TLcdAIXM51Property
initialized with the given role value. In case the given role value is null
, the END_POINT_PROPERTY
property is set to null
.
The point used to indicate the end of a segment.
setEndPoint
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the END_POINT_PROPERTY
property.public TLcdAIXM51Curve getTrajectory()
TRAJECTORY_PROPERTY
property. Returns null
if the value of the TRAJECTORY_PROPERTY
property is null
.
The path of the moving aircraft on the segment leg.
getTrajectory
in class TLcdAIXM51AbstractSegmentLegTimeSlice
TRAJECTORY_PROPERTY
property.TLcdAIXM51Property
public void setTrajectory(TLcdAIXM51Curve aValue)
trajectory
element. to a new instance of the association class TLcdAIXM51Property
initialized with the given role value. In case the given role value is null
, the TRAJECTORY_PROPERTY
property is set to null
.
The path of the moving aircraft on the segment leg.
setTrajectory
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the TRAJECTORY_PROPERTY
property.public TLcdAIXM51TerminalSegmentPoint getArcCentre()
ARC_CENTRE_PROPERTY
property. Returns null
if the value of the ARC_CENTRE_PROPERTY
property is null
.
The center point used to define an arc.
getArcCentre
in class TLcdAIXM51AbstractSegmentLegTimeSlice
ARC_CENTRE_PROPERTY
property.TLcdAIXM51Property
public void setArcCentre(TLcdAIXM51TerminalSegmentPoint aValue)
arcCentre
element. to a new instance of the association class TLcdAIXM51Property
initialized with the given role value. In case the given role value is null
, the ARC_CENTRE_PROPERTY
property is set to null
.
The center point used to define an arc.
setArcCentre
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the ARC_CENTRE_PROPERTY
property.public TLcdAIXM51Feature<TLcdAIXM51AngleIndicationTimeSlice> getAngle()
ANGLE_PROPERTY
property. Returns null
if the value of the ANGLE_PROPERTY
property is null
.
The angle defined to limit aircraft trajectory.
getAngle
in class TLcdAIXM51AbstractSegmentLegTimeSlice
ANGLE_PROPERTY
property.TLcdAIXM51FeatureAssociation
public void setAngle(TLcdAIXM51Feature<TLcdAIXM51AngleIndicationTimeSlice> aValue)
angle
element. to a new instance of the association class TLcdAIXM51FeatureAssociation
initialized with the given role value. In case the given role value is null
, the ANGLE_PROPERTY
property is set to null
.
The angle defined to limit aircraft trajectory.
setAngle
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the ANGLE_PROPERTY
property.public TLcdAIXM51Feature<TLcdAIXM51DistanceIndicationTimeSlice> getDistance()
DISTANCE_PROPERTY
property. Returns null
if the value of the DISTANCE_PROPERTY
property is null
.
The distance defined to limit aircraft trajectory.
getDistance
in class TLcdAIXM51AbstractSegmentLegTimeSlice
DISTANCE_PROPERTY
property.TLcdAIXM51FeatureAssociation
public void setDistance(TLcdAIXM51Feature<TLcdAIXM51DistanceIndicationTimeSlice> aValue)
distance
element. to a new instance of the association class TLcdAIXM51FeatureAssociation
initialized with the given role value. In case the given role value is null
, the DISTANCE_PROPERTY
property is set to null
.
The distance defined to limit aircraft trajectory.
setDistance
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the DISTANCE_PROPERTY
property.public List<TLcdAIXM51AircraftCharacteristic> getAircraftCategory()
AIRCRAFT_CATEGORY_PROPERTY
property adapted to a list of TLcdAIXM51AircraftCharacteristic
instances.
Classification of aircraft based on 1.3 times stall speed in landing configuration at maximum certified landing mass.
getAircraftCategory
in class TLcdAIXM51AbstractSegmentLegTimeSlice
AIRCRAFT_CATEGORY_PROPERTY
property adapted to a list of TLcdAIXM51AircraftCharacteristic
instances.TLcdAIXM51Property
public TLcdAIXM51HoldingUse getHolding()
HOLDING_PROPERTY
property. Returns null
if the value of the HOLDING_PROPERTY
property is null
.
Established holding used on a procedure.
getHolding
in class TLcdAIXM51AbstractSegmentLegTimeSlice
HOLDING_PROPERTY
property.TLcdAIXM51Property
public void setHolding(TLcdAIXM51HoldingUse aValue)
holding
element. to a new instance of the association class TLcdAIXM51Property
initialized with the given role value. In case the given role value is null
, the HOLDING_PROPERTY
property is set to null
.
Established holding used on a procedure.
setHolding
in class TLcdAIXM51AbstractSegmentLegTimeSlice
aValue
- the role value to set for the HOLDING_PROPERTY
property.public List<TLcdAIXM51ObstacleAssessmentArea> getDesignSurface()
DESIGN_SURFACE_PROPERTY
property adapted to a list of TLcdAIXM51ObstacleAssessmentArea
instances.
An evaluation area used when designing a procedure segment to insure safety of aircraft
getDesignSurface
in class TLcdAIXM51AbstractSegmentLegTimeSlice
DESIGN_SURFACE_PROPERTY
property adapted to a list of TLcdAIXM51ObstacleAssessmentArea
instances.TLcdAIXM51Property
public List<TLcdAIXM51Note> getAnnotation()
ANNOTATION_PROPERTY
property adapted to a list of TLcdAIXM51Note
instances.getAnnotation
in class TLcdAIXM51AbstractSegmentLegTimeSlice
ANNOTATION_PROPERTY
property adapted to a list of TLcdAIXM51Note
instances.TLcdAIXM51Property
public TLcdAIXM51Feature<TLcdAIXM51InstrumentApproachProcedureTimeSlice> getApproach()
APPROACH_PROPERTY
property. Returns null
if the value of the APPROACH_PROPERTY
property is null
.
(ICAO) A series of predetermined manoeuvres by reference to flight instruments with specified protection from obstacles from the initial approach fix, or where applicable , from the beginning of a defined arrival route to a point from which a landing can be completed and thereafter, if a landing is not completed, to a position at which holding or en route obstacle clearance criteria apply.
getApproach
in class TLcdAIXM51AbstractApproachLegTimeSlice
APPROACH_PROPERTY
property.TLcdAIXM51FeatureAssociation
public void setApproach(TLcdAIXM51Feature<TLcdAIXM51InstrumentApproachProcedureTimeSlice> aValue)
approach
element. to a new instance of the association class TLcdAIXM51FeatureAssociation
initialized with the given role value. In case the given role value is null
, the APPROACH_PROPERTY
property is set to null
.
(ICAO) A series of predetermined manoeuvres by reference to flight instruments with specified protection from obstacles from the initial approach fix, or where applicable , from the beginning of a defined arrival route to a point from which a landing can be completed and thereafter, if a landing is not completed, to a position at which holding or en route obstacle clearance criteria apply.
setApproach
in class TLcdAIXM51AbstractApproachLegTimeSlice
aValue
- the role value to set for the APPROACH_PROPERTY
property.public Double getRequiredNavigationPerformance()
REQUIRED_NAVIGATION_PERFORMANCE_PROPERTY
property. Returns null
if the value of the REQUIRED_NAVIGATION_PERFORMANCE_PROPERTY
property is null
.
[ICAO] Required navigation performance (RNP). [ICAO] Specifies the minimum navigation performance accuracy required in an airspace. It is the navigation performance accuracy of all the user and navigation system combinations within an airspace. Note: It is a tolerance factor for flying. The factor is taken into consideration when determining protected airspace for aircraft.
REQUIRED_NAVIGATION_PERFORMANCE_PROPERTY
property.TLcdAIXM51Optional
public void setRequiredNavigationPerformance(Double aValue)
requiredNavigationPerformance
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the REQUIRED_NAVIGATION_PERFORMANCE_PROPERTY
property is set to null
.
[ICAO] Required navigation performance (RNP). [ICAO] Specifies the minimum navigation performance accuracy required in an airspace. It is the navigation performance accuracy of all the user and navigation system combinations within an airspace. Note: It is a tolerance factor for flying. The factor is taken into consideration when determining protected airspace for aircraft.
aValue
- the role value to set for the REQUIRED_NAVIGATION_PERFORMANCE_PROPERTY
property.public List<TLcdAIXM51AbstractExtension> getExtension()
EXTENSION_PROPERTY
property adapted to a list of TLcdAIXM51AbstractExtension
instances.EXTENSION_PROPERTY
property adapted to a list of TLcdAIXM51AbstractExtension
instances.TLcdAIXM51Link
public ELcdAIXM51Interpretation getInterpretation()
interpretation
element.
Property indicating how the timeslice is to be interpreted. See the AIXM Temporality model for details.
INTERPRETATION_PROPERTY
property.public void setInterpretation(ELcdAIXM51Interpretation aValue)
interpretation
element.
Property indicating how the timeslice is to be interpreted. See the AIXM Temporality model for details.
aValue
- the value to set for the INTERPRETATION_PROPERTY
property.public long getSequenceNumber()
sequenceNumber
element.
Used for the identification of the Time Slice concerned. See the AIXM Temporality model for details.
SEQUENCE_NUMBER_PROPERTY
property.public void setSequenceNumber(long aValue)
sequenceNumber
element.
Used for the identification of the Time Slice concerned. See the AIXM Temporality model for details.
aValue
- the value to set for the SEQUENCE_NUMBER_PROPERTY
property.public long getCorrectionNumber()
correctionNumber
element.
Used for indicating the order of the corrections of a Time Slice. See the AIXM Temporality model for details.
CORRECTION_NUMBER_PROPERTY
property.public void setCorrectionNumber(long aValue)
correctionNumber
element.
Used for indicating the order of the corrections of a Time Slice. See the AIXM Temporality model for details.
aValue
- the value to set for the CORRECTION_NUMBER_PROPERTY
property.public TLcdAIXM51FeatureTimeSliceMetadataProperty getTimeSliceMetadata()
timeSliceMetadata
element.TIME_SLICE_METADATA_PROPERTY
property.public void setTimeSliceMetadata(TLcdAIXM51FeatureTimeSliceMetadataProperty aValue)
timeSliceMetadata
element.aValue
- the value to set for the TIME_SLICE_METADATA_PROPERTY
property.public TLcdGML32AbstractTimePrimitive getFeatureLifetime()
featureLifetime
element.
The start and end of life of the feature. See the AIXM Temporality model for details.
FEATURE_LIFETIME_PROPERTY
property.TLcdGML32TimePrimitiveProperty
public void setFeatureLifetime(TLcdGML32AbstractTimePrimitive aValue)
featureLifetime
element.
The start and end of life of the feature. See the AIXM Temporality model for details.
aValue
- the value to set for the FEATURE_LIFETIME_PROPERTY
property.