public class TLcdAIXM51RunwayDirectionTimeSlice extends TLcdAIXM51AbstractAIXMTimeSlice
Modifier and Type | Field and Description |
---|---|
static TLcdDataProperty |
ANNOTATION_PROPERTY
Data property that maps to the
annotation element. |
static TLcdDataProperty |
APPROACH_MARKING_CONDITION_PROPERTY
Data property that maps to the
approachMarkingCondition element. |
static TLcdDataProperty |
APPROACH_MARKING_TYPE_PROPERTY
Data property that maps to the
approachMarkingType element. |
static TLcdDataProperty |
AVAILABILITY_PROPERTY
Data property that maps to the
availability element. |
static TLcdDataProperty |
CLASS_LIGHTING_JAR_PROPERTY
Data property that maps to the
classLightingJAR element. |
static TLcdDataProperty |
CORRECTION_NUMBER_PROPERTY
Data property that maps to the
correctionNumber element. |
static TLcdDataProperty |
DESIGNATOR_PROPERTY
Data property that maps to the
designator element. |
static TLcdDataProperty |
ELEVATION_TDZ_ACCURACY_PROPERTY
Data property that maps to the
elevationTDZAccuracy element. |
static TLcdDataProperty |
ELEVATION_TDZ_PROPERTY
Data property that maps to the
elevationTDZ element. |
static TLcdDataProperty |
EXTENSION_PROPERTY
Data property that maps to the
extension element. |
static TLcdDataProperty |
FEATURE_LIFETIME_PROPERTY
Data property that maps to the
featureLifetime element. |
static TLcdDataProperty |
INTERPRETATION_PROPERTY
Data property that maps to the
interpretation element. |
static TLcdDataProperty |
MAGNETIC_BEARING_PROPERTY
Data property that maps to the
magneticBearing element. |
static TLcdDataProperty |
PATTERN_VFR_PROPERTY
Data property that maps to the
patternVFR element. |
static TLcdDataProperty |
PRECISION_APPROACH_GUIDANCE_PROPERTY
Data property that maps to the
precisionApproachGuidance element. |
static TLcdDataProperty |
SEQUENCE_NUMBER_PROPERTY
Data property that maps to the
sequenceNumber element. |
static TLcdDataProperty |
SLOPE_TDZ_PROPERTY
Data property that maps to the
slopeTDZ element. |
static TLcdDataProperty |
STARTING_ELEMENT_PROPERTY
Data property that maps to the
startingElement element. |
static TLcdDataProperty |
TIME_SLICE_METADATA_PROPERTY
Data property that maps to the
timeSliceMetadata element. |
static TLcdDataProperty |
TRUE_BEARING_ACCURACY_PROPERTY
Data property that maps to the
trueBearingAccuracy element. |
static TLcdDataProperty |
TRUE_BEARING_PROPERTY
Data property that maps to the
trueBearing element. |
static TLcdDataProperty |
USED_RUNWAY_PROPERTY
Data property that maps to the
usedRunway element. |
DATA_SOURCE_PROPERTY, VALID_TIME_PROPERTY
DESCRIPTION_PROPERTY, DESCRIPTION_REFERENCE_PROPERTY, ID_PROPERTY, IDENTIFIER_PROPERTY, META_DATA_PROPERTY_PROPERTY, NAME_PROPERTY
Constructor and Description |
---|
TLcdAIXM51RunwayDirectionTimeSlice() |
TLcdAIXM51RunwayDirectionTimeSlice(TLcdDataType aType) |
Modifier and Type | Method and Description |
---|---|
List<TLcdAIXM51Note> |
getAnnotation()
Gets the value of the
ANNOTATION_PROPERTY property adapted to a list of TLcdAIXM51Note instances. |
TLcdAIXM51CodeMarkingCondition |
getApproachMarkingCondition()
Returns the role value contained in the value of the
APPROACH_MARKING_CONDITION_PROPERTY property. |
TLcdAIXM51CodeRunwayMarking |
getApproachMarkingType()
Returns the role value contained in the value of the
APPROACH_MARKING_TYPE_PROPERTY property. |
List<TLcdAIXM51ManoeuvringAreaAvailability> |
getAvailability()
Gets the value of the
AVAILABILITY_PROPERTY property adapted to a list of TLcdAIXM51ManoeuvringAreaAvailability instances. |
TLcdAIXM51CodeLightingJAR |
getClassLightingJAR()
Returns the role value contained in the value of the
CLASS_LIGHTING_JAR_PROPERTY property. |
long |
getCorrectionNumber()
Returns the value of the property that maps to the
correctionNumber element. |
String |
getDesignator()
Returns the role value contained in the value of the
DESIGNATOR_PROPERTY property. |
TLcdAIXM51ValDistanceVertical |
getElevationTDZ()
Returns the value of the property that maps to the
elevationTDZ element. |
TLcdAIXM51ValDistance |
getElevationTDZAccuracy()
Returns the value of the property that maps to the
elevationTDZAccuracy element. |
List<TLcdAIXM51AbstractExtension> |
getExtension()
Gets the value of the
EXTENSION_PROPERTY property adapted to a list of TLcdAIXM51AbstractExtension instances. |
TLcdGML32AbstractTimePrimitive |
getFeatureLifetime()
Returns the value of the property that maps to the
featureLifetime element. |
ELcdAIXM51Interpretation |
getInterpretation()
Returns the value of the property that maps to the
interpretation element. |
Double |
getMagneticBearing()
Returns the role value contained in the value of the
MAGNETIC_BEARING_PROPERTY property. |
TLcdAIXM51CodeDirectionTurn |
getPatternVFR()
Returns the role value contained in the value of the
PATTERN_VFR_PROPERTY property. |
TLcdAIXM51CodeApproachGuidance |
getPrecisionApproachGuidance()
Returns the role value contained in the value of the
PRECISION_APPROACH_GUIDANCE_PROPERTY property. |
long |
getSequenceNumber()
Returns the value of the property that maps to the
sequenceNumber element. |
Double |
getSlopeTDZ()
Returns the role value contained in the value of the
SLOPE_TDZ_PROPERTY property. |
TLcdAIXM51Feature<TLcdAIXM51RunwayElementTimeSlice> |
getStartingElement()
Returns the role value contained in the value of the
STARTING_ELEMENT_PROPERTY property. |
TLcdAIXM51FeatureTimeSliceMetadataProperty |
getTimeSliceMetadata()
Returns the value of the property that maps to the
timeSliceMetadata element. |
Double |
getTrueBearing()
Returns the role value contained in the value of the
TRUE_BEARING_PROPERTY property. |
Double |
getTrueBearingAccuracy()
Returns the role value contained in the value of the
TRUE_BEARING_ACCURACY_PROPERTY property. |
TLcdAIXM51Feature<TLcdAIXM51RunwayTimeSlice> |
getUsedRunway()
Returns the role value contained in the value of the
USED_RUNWAY_PROPERTY property. |
void |
setApproachMarkingCondition(TLcdAIXM51CodeMarkingCondition aValue)
Sets the value of the property that maps to the
approachMarkingCondition element. |
void |
setApproachMarkingType(TLcdAIXM51CodeRunwayMarking aValue)
Sets the value of the property that maps to the
approachMarkingType element. |
void |
setClassLightingJAR(TLcdAIXM51CodeLightingJAR aValue)
Sets the value of the property that maps to the
classLightingJAR element. |
void |
setCorrectionNumber(long aValue)
Sets the value of the property that maps to the
correctionNumber element. |
void |
setDesignator(String aValue)
Sets the value of the property that maps to the
designator element. |
void |
setElevationTDZ(TLcdAIXM51ValDistanceVertical aValue)
Sets the value of the property that maps to the
elevationTDZ element. |
void |
setElevationTDZAccuracy(TLcdAIXM51ValDistance aValue)
Sets the value of the property that maps to the
elevationTDZAccuracy element. |
void |
setFeatureLifetime(TLcdGML32AbstractTimePrimitive aValue)
Sets the value of the property that maps to the
featureLifetime element. |
void |
setInterpretation(ELcdAIXM51Interpretation aValue)
Sets the value of the property that maps to the
interpretation element. |
void |
setMagneticBearing(Double aValue)
Sets the value of the property that maps to the
magneticBearing element. |
void |
setPatternVFR(TLcdAIXM51CodeDirectionTurn aValue)
Sets the value of the property that maps to the
patternVFR element. |
void |
setPrecisionApproachGuidance(TLcdAIXM51CodeApproachGuidance aValue)
Sets the value of the property that maps to the
precisionApproachGuidance element. |
void |
setSequenceNumber(long aValue)
Sets the value of the property that maps to the
sequenceNumber element. |
void |
setSlopeTDZ(Double aValue)
Sets the value of the property that maps to the
slopeTDZ element. |
void |
setStartingElement(TLcdAIXM51Feature<TLcdAIXM51RunwayElementTimeSlice> aValue)
Sets the value of the property that maps to the
startingElement element. |
void |
setTimeSliceMetadata(TLcdAIXM51FeatureTimeSliceMetadataProperty aValue)
Sets the value of the property that maps to the
timeSliceMetadata element. |
void |
setTrueBearing(Double aValue)
Sets the value of the property that maps to the
trueBearing element. |
void |
setTrueBearingAccuracy(Double aValue)
Sets the value of the property that maps to the
trueBearingAccuracy element. |
void |
setUsedRunway(TLcdAIXM51Feature<TLcdAIXM51RunwayTimeSlice> aValue)
Sets the value of the property that maps to the
usedRunway element. |
clone, clone, collectShapes, contains2D, contains2D, contains3D, contains3D, getBeginValidTime, getBounds, getEndValidTime, getFocusPoint, getShape, getShapeCount, getTimeBounds, invalidateObject, setValue
getDataSource, getValidTime, setDataSource, setValidTime
getDescription, getDescriptionReference, getId, getIdentifier, getMetaDataProperty, getName, setDescription, setDescriptionReference, setId, setIdentifier
getDataType, getValue, getValue, hasValue, hasValue, setValue, toString
public static final TLcdDataProperty DESIGNATOR_PROPERTY
designator
element.
The possible values for this property are instances of TLcdAIXM51Optional<String>
.public static final TLcdDataProperty TRUE_BEARING_PROPERTY
trueBearing
element.
The possible values for this property are instances of TLcdAIXM51Optional<Double>
.public static final TLcdDataProperty TRUE_BEARING_ACCURACY_PROPERTY
trueBearingAccuracy
element.
The possible values for this property are instances of TLcdAIXM51Optional<Double>
.public static final TLcdDataProperty MAGNETIC_BEARING_PROPERTY
magneticBearing
element.
The possible values for this property are instances of TLcdAIXM51Optional<Double>
.public static final TLcdDataProperty PATTERN_VFR_PROPERTY
patternVFR
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeDirectionTurn>
.public static final TLcdDataProperty SLOPE_TDZ_PROPERTY
slopeTDZ
element.
The possible values for this property are instances of TLcdAIXM51Optional<Double>
.public static final TLcdDataProperty ELEVATION_TDZ_PROPERTY
elevationTDZ
element.
The possible values for this property are instances of TLcdAIXM51ValDistanceVertical
.public static final TLcdDataProperty ELEVATION_TDZ_ACCURACY_PROPERTY
elevationTDZAccuracy
element.
The possible values for this property are instances of TLcdAIXM51ValDistance
.public static final TLcdDataProperty APPROACH_MARKING_TYPE_PROPERTY
approachMarkingType
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeRunwayMarking>
.public static final TLcdDataProperty APPROACH_MARKING_CONDITION_PROPERTY
approachMarkingCondition
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeMarkingCondition>
.public static final TLcdDataProperty CLASS_LIGHTING_JAR_PROPERTY
classLightingJAR
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeLightingJAR>
.public static final TLcdDataProperty PRECISION_APPROACH_GUIDANCE_PROPERTY
precisionApproachGuidance
element.
The possible values for this property are instances of TLcdAIXM51Optional<TLcdAIXM51CodeApproachGuidance>
.public static final TLcdDataProperty USED_RUNWAY_PROPERTY
usedRunway
element.
The possible values for this property are instances of TLcdAIXM51FeatureAssociation<TLcdAIXM51RunwayTimeSlice>
.public static final TLcdDataProperty STARTING_ELEMENT_PROPERTY
startingElement
element.
The possible values for this property are instances of TLcdAIXM51FeatureAssociation<TLcdAIXM51RunwayElementTimeSlice>
.public static final TLcdDataProperty ANNOTATION_PROPERTY
annotation
element.
The possible values for this property are instances of List<TLcdAIXM51Property<TLcdAIXM51Note>>
.public static final TLcdDataProperty AVAILABILITY_PROPERTY
availability
element.
The possible values for this property are instances of List<TLcdAIXM51Property<TLcdAIXM51ManoeuvringAreaAvailability>>
.public static final TLcdDataProperty EXTENSION_PROPERTY
extension
element.
The possible values for this property are instances of List<TLcdAIXM51Link<TLcdAIXM51AbstractExtension>>
.public static final TLcdDataProperty INTERPRETATION_PROPERTY
interpretation
element.
The possible values for this property are instances of ELcdAIXM51Interpretation
.public static final TLcdDataProperty SEQUENCE_NUMBER_PROPERTY
sequenceNumber
element.
The possible values for this property are instances of long
.public static final TLcdDataProperty CORRECTION_NUMBER_PROPERTY
correctionNumber
element.
The possible values for this property are instances of long
.public static final TLcdDataProperty TIME_SLICE_METADATA_PROPERTY
timeSliceMetadata
element.
The possible values for this property are instances of TLcdAIXM51FeatureTimeSliceMetadataProperty
.public static final TLcdDataProperty FEATURE_LIFETIME_PROPERTY
featureLifetime
element.
The possible values for this property are instances of TLcdGML32TimePrimitiveProperty
.public TLcdAIXM51RunwayDirectionTimeSlice()
public TLcdAIXM51RunwayDirectionTimeSlice(TLcdDataType aType)
public String getDesignator()
DESIGNATOR_PROPERTY
property. Returns null
if the value of the DESIGNATOR_PROPERTY
property is null
.
The full textual designator of the landing and take-off direction. Examples: 27, 35L, 01R.
DESIGNATOR_PROPERTY
property.TLcdAIXM51Optional
public void setDesignator(String aValue)
designator
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the DESIGNATOR_PROPERTY
property is set to null
.
The full textual designator of the landing and take-off direction. Examples: 27, 35L, 01R.
aValue
- the role value to set for the DESIGNATOR_PROPERTY
property.public Double getTrueBearing()
TRUE_BEARING_PROPERTY
property. Returns null
if the value of the TRUE_BEARING_PROPERTY
property is null
.
The measured angle between the runway direction and True North at a given position. Note : The True North is the north point at which the meridian lines meet.
TRUE_BEARING_PROPERTY
property.TLcdAIXM51Optional
public void setTrueBearing(Double aValue)
trueBearing
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the TRUE_BEARING_PROPERTY
property is set to null
.
The measured angle between the runway direction and True North at a given position. Note : The True North is the north point at which the meridian lines meet.
aValue
- the role value to set for the TRUE_BEARING_PROPERTY
property.public Double getTrueBearingAccuracy()
TRUE_BEARING_ACCURACY_PROPERTY
property. Returns null
if the value of the TRUE_BEARING_ACCURACY_PROPERTY
property is null
.
Accuracy of the measured angle between the runway direction and True North at a given position.
TRUE_BEARING_ACCURACY_PROPERTY
property.TLcdAIXM51Optional
public void setTrueBearingAccuracy(Double aValue)
trueBearingAccuracy
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the TRUE_BEARING_ACCURACY_PROPERTY
property is set to null
.
Accuracy of the measured angle between the runway direction and True North at a given position.
aValue
- the role value to set for the TRUE_BEARING_ACCURACY_PROPERTY
property.public Double getMagneticBearing()
MAGNETIC_BEARING_PROPERTY
property. Returns null
if the value of the MAGNETIC_BEARING_PROPERTY
property is null
.
The measured angle between the runway direction and Magnetic North at a given position.
MAGNETIC_BEARING_PROPERTY
property.TLcdAIXM51Optional
public void setMagneticBearing(Double aValue)
magneticBearing
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the MAGNETIC_BEARING_PROPERTY
property is set to null
.
The measured angle between the runway direction and Magnetic North at a given position.
aValue
- the role value to set for the MAGNETIC_BEARING_PROPERTY
property.public TLcdAIXM51CodeDirectionTurn getPatternVFR()
PATTERN_VFR_PROPERTY
property. Returns null
if the value of the PATTERN_VFR_PROPERTY
property is null
.
A code indicating the direction of the VFR flight pattern at an aerodrome/heliport, i.e. left or right.
PATTERN_VFR_PROPERTY
property.TLcdAIXM51Optional
public void setPatternVFR(TLcdAIXM51CodeDirectionTurn aValue)
patternVFR
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the PATTERN_VFR_PROPERTY
property is set to null
.
A code indicating the direction of the VFR flight pattern at an aerodrome/heliport, i.e. left or right.
aValue
- the role value to set for the PATTERN_VFR_PROPERTY
property.public Double getSlopeTDZ()
SLOPE_TDZ_PROPERTY
property. Returns null
if the value of the SLOPE_TDZ_PROPERTY
property is null
.
Touchdown zone longitudinal slope (slope of 1/3 of the runway length from threshold or first 3000 feet for runways longer than 9000 feet)
SLOPE_TDZ_PROPERTY
property.TLcdAIXM51Optional
public void setSlopeTDZ(Double aValue)
slopeTDZ
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the SLOPE_TDZ_PROPERTY
property is set to null
.
Touchdown zone longitudinal slope (slope of 1/3 of the runway length from threshold or first 3000 feet for runways longer than 9000 feet)
aValue
- the role value to set for the SLOPE_TDZ_PROPERTY
property.public TLcdAIXM51ValDistanceVertical getElevationTDZ()
elevationTDZ
element.
Elevation of touch down zone: The value of the highest elevation of the runway Touch Down Zone (TDZ).
ELEVATION_TDZ_PROPERTY
property.public void setElevationTDZ(TLcdAIXM51ValDistanceVertical aValue)
elevationTDZ
element.
Elevation of touch down zone: The value of the highest elevation of the runway Touch Down Zone (TDZ).
aValue
- the value to set for the ELEVATION_TDZ_PROPERTY
property.public TLcdAIXM51ValDistance getElevationTDZAccuracy()
elevationTDZAccuracy
element.
The accuracy of the reported Touch Down Zone elevation
ELEVATION_TDZ_ACCURACY_PROPERTY
property.public void setElevationTDZAccuracy(TLcdAIXM51ValDistance aValue)
elevationTDZAccuracy
element.
The accuracy of the reported Touch Down Zone elevation
aValue
- the value to set for the ELEVATION_TDZ_ACCURACY_PROPERTY
property.public TLcdAIXM51CodeRunwayMarking getApproachMarkingType()
APPROACH_MARKING_TYPE_PROPERTY
property. Returns null
if the value of the APPROACH_MARKING_TYPE_PROPERTY
property is null
.
Type of marking related to landing categories such as precision, non-precision and basic.
APPROACH_MARKING_TYPE_PROPERTY
property.TLcdAIXM51Optional
public void setApproachMarkingType(TLcdAIXM51CodeRunwayMarking aValue)
approachMarkingType
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the APPROACH_MARKING_TYPE_PROPERTY
property is set to null
.
Type of marking related to landing categories such as precision, non-precision and basic.
aValue
- the role value to set for the APPROACH_MARKING_TYPE_PROPERTY
property.public TLcdAIXM51CodeMarkingCondition getApproachMarkingCondition()
APPROACH_MARKING_CONDITION_PROPERTY
property. Returns null
if the value of the APPROACH_MARKING_CONDITION_PROPERTY
property is null
.
The quality of the runway marking such as good, fair, poor and other.
APPROACH_MARKING_CONDITION_PROPERTY
property.TLcdAIXM51Optional
public void setApproachMarkingCondition(TLcdAIXM51CodeMarkingCondition aValue)
approachMarkingCondition
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the APPROACH_MARKING_CONDITION_PROPERTY
property is set to null
.
The quality of the runway marking such as good, fair, poor and other.
aValue
- the role value to set for the APPROACH_MARKING_CONDITION_PROPERTY
property.public TLcdAIXM51CodeLightingJAR getClassLightingJAR()
CLASS_LIGHTING_JAR_PROPERTY
property. Returns null
if the value of the CLASS_LIGHTING_JAR_PROPERTY
property is null
.
Classification of the approach lighting system using as criteria JAR-OPS 1 - Subpart E, Appendix 1 to 1.430
CLASS_LIGHTING_JAR_PROPERTY
property.TLcdAIXM51Optional
public void setClassLightingJAR(TLcdAIXM51CodeLightingJAR aValue)
classLightingJAR
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the CLASS_LIGHTING_JAR_PROPERTY
property is set to null
.
Classification of the approach lighting system using as criteria JAR-OPS 1 - Subpart E, Appendix 1 to 1.430
aValue
- the role value to set for the CLASS_LIGHTING_JAR_PROPERTY
property.public TLcdAIXM51CodeApproachGuidance getPrecisionApproachGuidance()
PRECISION_APPROACH_GUIDANCE_PROPERTY
property. Returns null
if the value of the PRECISION_APPROACH_GUIDANCE_PROPERTY
property is null
.
Degree to which navigation aids provide accurate approach guidance. Precision approaches utilize both lateral (course) and vertical (glideslope) information
PRECISION_APPROACH_GUIDANCE_PROPERTY
property.TLcdAIXM51Optional
public void setPrecisionApproachGuidance(TLcdAIXM51CodeApproachGuidance aValue)
precisionApproachGuidance
element. to a new instance of the association class TLcdAIXM51Optional
initialized with the given role value. In case the given role value is null
, the PRECISION_APPROACH_GUIDANCE_PROPERTY
property is set to null
.
Degree to which navigation aids provide accurate approach guidance. Precision approaches utilize both lateral (course) and vertical (glideslope) information
aValue
- the role value to set for the PRECISION_APPROACH_GUIDANCE_PROPERTY
property.public TLcdAIXM51Feature<TLcdAIXM51RunwayTimeSlice> getUsedRunway()
USED_RUNWAY_PROPERTY
property. Returns null
if the value of the USED_RUNWAY_PROPERTY
property is null
.
The runway used by the RunwayDirection.
USED_RUNWAY_PROPERTY
property.TLcdAIXM51FeatureAssociation
public void setUsedRunway(TLcdAIXM51Feature<TLcdAIXM51RunwayTimeSlice> aValue)
usedRunway
element. to a new instance of the association class TLcdAIXM51FeatureAssociation
initialized with the given role value. In case the given role value is null
, the USED_RUNWAY_PROPERTY
property is set to null
.
The runway used by the RunwayDirection.
aValue
- the role value to set for the USED_RUNWAY_PROPERTY
property.public TLcdAIXM51Feature<TLcdAIXM51RunwayElementTimeSlice> getStartingElement()
STARTING_ELEMENT_PROPERTY
property. Returns null
if the value of the STARTING_ELEMENT_PROPERTY
property is null
.
The RunwayElement that starts the RunwayDirection.
STARTING_ELEMENT_PROPERTY
property.TLcdAIXM51FeatureAssociation
public void setStartingElement(TLcdAIXM51Feature<TLcdAIXM51RunwayElementTimeSlice> aValue)
startingElement
element. to a new instance of the association class TLcdAIXM51FeatureAssociation
initialized with the given role value. In case the given role value is null
, the STARTING_ELEMENT_PROPERTY
property is set to null
.
The RunwayElement that starts the RunwayDirection.
aValue
- the role value to set for the STARTING_ELEMENT_PROPERTY
property.public List<TLcdAIXM51Note> getAnnotation()
ANNOTATION_PROPERTY
property adapted to a list of TLcdAIXM51Note
instances.ANNOTATION_PROPERTY
property adapted to a list of TLcdAIXM51Note
instances.TLcdAIXM51Property
public List<TLcdAIXM51ManoeuvringAreaAvailability> getAvailability()
AVAILABILITY_PROPERTY
property adapted to a list of TLcdAIXM51ManoeuvringAreaAvailability
instances.
The operational status of the RunwayDirection.
AVAILABILITY_PROPERTY
property adapted to a list of TLcdAIXM51ManoeuvringAreaAvailability
instances.TLcdAIXM51Property
public List<TLcdAIXM51AbstractExtension> getExtension()
EXTENSION_PROPERTY
property adapted to a list of TLcdAIXM51AbstractExtension
instances.EXTENSION_PROPERTY
property adapted to a list of TLcdAIXM51AbstractExtension
instances.TLcdAIXM51Link
public ELcdAIXM51Interpretation getInterpretation()
interpretation
element.
Property indicating how the timeslice is to be interpreted. See the AIXM Temporality model for details.
INTERPRETATION_PROPERTY
property.public void setInterpretation(ELcdAIXM51Interpretation aValue)
interpretation
element.
Property indicating how the timeslice is to be interpreted. See the AIXM Temporality model for details.
aValue
- the value to set for the INTERPRETATION_PROPERTY
property.public long getSequenceNumber()
sequenceNumber
element.
Used for the identification of the Time Slice concerned. See the AIXM Temporality model for details.
SEQUENCE_NUMBER_PROPERTY
property.public void setSequenceNumber(long aValue)
sequenceNumber
element.
Used for the identification of the Time Slice concerned. See the AIXM Temporality model for details.
aValue
- the value to set for the SEQUENCE_NUMBER_PROPERTY
property.public long getCorrectionNumber()
correctionNumber
element.
Used for indicating the order of the corrections of a Time Slice. See the AIXM Temporality model for details.
CORRECTION_NUMBER_PROPERTY
property.public void setCorrectionNumber(long aValue)
correctionNumber
element.
Used for indicating the order of the corrections of a Time Slice. See the AIXM Temporality model for details.
aValue
- the value to set for the CORRECTION_NUMBER_PROPERTY
property.public TLcdAIXM51FeatureTimeSliceMetadataProperty getTimeSliceMetadata()
timeSliceMetadata
element.TIME_SLICE_METADATA_PROPERTY
property.public void setTimeSliceMetadata(TLcdAIXM51FeatureTimeSliceMetadataProperty aValue)
timeSliceMetadata
element.aValue
- the value to set for the TIME_SLICE_METADATA_PROPERTY
property.public TLcdGML32AbstractTimePrimitive getFeatureLifetime()
featureLifetime
element.
The start and end of life of the feature. See the AIXM Temporality model for details.
FEATURE_LIFETIME_PROPERTY
property.TLcdGML32TimePrimitiveProperty
public void setFeatureLifetime(TLcdGML32AbstractTimePrimitive aValue)
featureLifetime
element.
The start and end of life of the feature. See the AIXM Temporality model for details.
aValue
- the value to set for the FEATURE_LIFETIME_PROPERTY
property.